The Eaton NubisNet IoT-Gateways are intended to be used for Cloud communication via MQTT in industrial applications. They can also be used as a VPN Client to set up a remote connection to applications.
With the protection class IP 20 the Gateway is intended to be installed in electrical cabinets to ensure protection against environmental damage. In case of a metal electrical cabinet it may be required to use separate antennas for Gateways with radio connection (LTE, WLAN). Such antennas are offered by Eaton as accessories.
From time to time Eaton will release new versions of the Firmware and / or Software of the Gateways. These new versions may include patches to improve the cyber security of the Gateways. Eaton will update the Gateway support section of this page as soon as the new Firmware is available. The Gateways should not be operated with any other than the latest Firmware version.
Installation and electrical connection
The following links will direct you to the data sheets of the gateways:
By clicking “Scan” your gateway should be found automatically
Set IP configuration
Make sure your PC and Gateway are in the same network!
(e.g. PC: 192.168.119.14 and Gateway: 192.168.119.10)
Factory rest
In case a factory reset is required please take the following steps:
Disconnect the power supply from the gateway
See the reset button mark in yellow on the below pictures
Press and hold the reset button . Connect the power supply to the gateway.
Wait until the gateway confirms the reset process with all LEDs flashing twice.
Release the reset button.
Wait until the gateway has started up.
The factory reset is now complete
Gateway programming documentation
The complete Gateway documentation is available as online documentation after accessing the Gateway via Web-Browser. The default credentials are:
username: NubisNet-user
password: NubisNet-user
Username and password have to be changed after the first login.
In addition to the online documentation an Application Note has been created to guide the user through the different recommended settings for the operation of the gateway on the Brightlayer Industrial Machinery environment.